Zoom 4321F Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 6
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
Each system includes: Choice of camera/lens, darkroom with manual or motorized platform, white light illuminator, three filters, choice
of UV transilluminator and VisionWorksLS software. Installation Qualification and Operational Qualification (IQ/OQ) documentation is
available. System configurations may vary by country. Contact UVP for system details.
Epi Lights: White Light, 365nm UV, 460-470nm Blue
Transillumination: White Light LED Plate
Choice of M-26XV (302nm, 25x26cm) or LMS-26 (254/
302/365nm, 21x26cm); Selection may vary by country
Emission Filters: Five position motorized wheel with EtBr (580-630nm),
SYBR Green (510-560nm), SYBR Gold (520-620nm)
Additional filters available; refer to UVP’s filter chart
for details.
Controls: Software automated with templates
Platform: Motorized with 10 in. range
or Manual control
Dimensions: 17.5W x 17.5D x 32H in.
(44.5 x 44.5 x 81.3cm) plus camera cover
Ordering Information
BioSpectrum 310 Imaging System (GelCam 310 Camera)
BioSpectrum 415 Imaging System (Chemi 415 Camera)
BioSpectrum 600 Imaging System (OptiChemi 600 Camera)
BioSpectrum 810 Imaging System (MegaCam 810 Camera)
Darkroom Specifications
Specifications subject to change without notice. Ó UVP, LLC 2011 Lit: BioSpectrum R1211
Web Site: uvp.com
UVP, LLC 2066 W. 11th St., Upland, CA 91786 | E-Mail: [email protected]
Tel: (800) 452-6788 | (909) 946-3197 | Fax: (909) 946-3597
Ultra-Violet Products Ltd. Unit 1, Trinity Hall Farm Estate,
Nuffield Road, Cambridge CB4 1TG UK | E-Mail: [email protected]
Tel: +44(0)1223-420022 | Fax: +44(0)1223-420561
For a quote or additional information contact:
BioSpectrum and VisionWorks are registered trademarks of UVP, LLC. BioLite is a trademark of UVP, LLC.
All other tradenames are recognized as owned by their respective owners.
Ask about software network versions for multiple users.
Capabilities: Image acquisition/analysis
Controls: Interface with camera, darkroom
Tools: Macros and templates, plus image
enhancement tools
Documentation: Create reports and export data
Compatibility: Windows XP, Windows 7
VisionWorksLS Software
Camera Specifications
Ordering Information & Specifications
VisionWorksLS analysis includes comprehensive tools for in-depth image
analysis. The easy to use, intuitive functions automate your experiments
with accurate quantitation, generation of lane profile graphs, plus intensity
histograms, concentration curves and much more!
1D lane analysis Area density
Plant imaging Molecular weights
Protein quantitation Quantitative PCR
Western blot densitometry Colony counting
GFP expression Multiplexing and more
Researchers can personalize their workspace preferences and save theprofiles by
user name. Also set up user accounts with passwords to protect user data.
User-defined templates are great time savers and allow users to set and save
darkroom and camera settings for quick and easy capture of samples. Also select
from several pre-set capture templates which include a template for acquiring a
series of multiple exposures of chemiluminescent Western blots.
Create personalized, custom macros to automate routine, time consuming
procedures involving image capture, enhancement, analysis and data archiving.
Record keystrokes that perform a series of complex functions within the software.
Assign a function key to the recorded macros for one-touch automation. The
macros simplify operations to prevent user errors. Macros can be used to
auto-adjust dark chemi blots to perfection.
Area Density for Western Blots. Quickly determine
relative intensities of Western blots and more.
Create detailed and user-configured reports showing extensive analysis
results on MW, Rf, precise position of bands, band intensities, area density
calculations and more. Export data to Excel.
VisionWorksLS software enables image history tracking with change logs to
support 21 CFR Part 11 compliance.
Image History. Record changes to images.
Record Macros. For repeat procedures.
Name and describe the custom macro
Acquire a typical image for analysis
Record the keystrokes required for analysis
Save the custom macro in the Macro dropdown menu
Reports, Export Data and History Tracking
User Profiles, Templates and Preferences
One-Touch Automated Macros
VisionWorksLS Capabilities
Templates. Define custom settings.
Thermal Printer
The thermal printer generates
archive quality, 256 gray scale
prints. Glossy and matt papers
are available. Paper rolls easily
install in seconds.
BioLite
TM
Light Source
The BioLite is a directed epi or
transillumination fiber optic
source with filters for excitation of
fluorescent multiplexed western
blots, DIGE 2D gels, PAGE gels,
microplates and more. Refer to
UVP’s filter chart for filter details.
BioSpectrum Accessories
Image Analysis Capabilities
Specifications MegaCam 810 OptiChemi 600 Chemi 415 GelCam 310
CCD Bit Depth 16 bit 16 bit 16 bit 12 bit
File Bit Depth (A/D) 16 bit 16 bit 16 bit 16 bit
Grayscale Range 65,536 65,536 65,536 65,536
Pixel Resolution 3296 x 2472 2184 x 1472 1360 x 1024 1600 x 1200
Megapixels 8.1 3.2 1.4 2.0
Cooling Type
-35
O
C
From Ambient;
Peltier
-60
O
C
From Ambient;
4-Stage Peltier
-35
O
C
From Ambient;
Peltier
None
Binning Modes 1x1 thru 8x8 1x1 thru 16x16 1x1 thru 8x8 None
PC Interface Connection USB 2.0 Ethernet USB 2.0 USB 2.0
Quantum Efficiency
Peak & Chemi 425nm
50% & 44% 90% & 63% 62% & 53% ---
Lens Options
f/1.2 50mm | f/1.4 30mm
| f/2.8 24-70mm
f/1.2 50mm | f/1.4 30mm
| f/2.8 24-70mm
f/1.2 12.5-75mm f/1.2 12.5-75mm
Follow UVP ... twitter/uvpbioimaging
Automated Imaging Technology to
Simplify Your Workflow!
Contact UVP for current system/camera specifications.
Vista de pagina 4
1 2 3 4 5 6

Comentarios a estos manuales

Sin comentarios